Human CXCR4 Biotinylated MAb (Clone 12G5)  100 TESTS Recombinant Rat C-Reactive Protein/CRP Protein, CF  200 UG Recombinant Mouse Osteopontin (OPN) Protein, CF  50 UG Recombinant Mouse Osteopontin (OPN) Protein  50 UG Recombinant Mouse TNF-alpha (aa 84-235) Protein, CF  10 UG Recombinant Mouse TNF-alpha (aa 84-235) Protein  10 UG

产品介绍

    基本参数

    详细说明

    • Assay Type

      Magnetic bead-based multiplex assay for the Luminex® MAGPIX® platform

    • Format

      96-well microplate and antibody-coated magnetic beads*

    • Analytes Detected

      Please see table below.

    • Performance Validation

      For standard curves, intra-assay and inter-assay precision, recovery, and linearity data for the different analyte-specific beads, please see product datasheets for corresponding individual Bead Sets (below).

     

    * Antibody-coated beads supplied in compatible Bead Sets, sold separately (see below).

     

    Product Features

    • Simultaneously detect multiple analytes

    • Magnetic format allows for easier wash steps

    • User selects specific analytes of interest

    • Requires small sample size

    • Undergoes similar validation testing as Quantikine® ELISA Kits

    • Precise and Specific

     

    Base Kit Contents

    • Standard Cocktail(s)

    • Bead Diluent

    • Biotin Antibody Diluent

    • Calibrator Diluent(s)

    • Streptavidin-PE

    • Wash Buffer Concentrate

    • Mixing Bottles

    • Round-bottom Microplate

    • Foil Plate Sealers

     

    Base Set Contents

    • Antibody-coated magnetic beads

    • Biotinylated detection antibody

     

    Information for Compatiable Analytes

    For performance data for the different analyte-specific beads, please see product datasheets for the compatible individual Bead Sets.

    AnalyteCatalog
    Number
    Sensitivity
    (pg/mL)
    High Standard Value*
    (pg/mL)
    Microparticle
    Region
    Clusterin
    64.3483,80020
    Cystatin C
    57.116,50019
    CXCL10/IP-10
    0.6933,11025
    Lipocalin-2/NGAL
    63.136,10027
    Osteopontin (OPN)
    247295,50028
    RBP4
    12447,40029
    TFF3
    11.511,00030
    TIM-1/KIM-1/HAVCR
    16.3116,00026
    *A standard curve must be generated each time an assay is run, utilizing values from the Standard Value Card included in the Base Kit.

     

    Validated Samples and Recommended Starting Dilution

    AnalyteSerumEDTA PlasmaHeparin PlasmaUrine
    Clusterin1:4,0001:4,0001:4,0001:10
    Cystatin C1:4,0001:4,0001:4,0001:10
    CXCL10/IP-101:101:101:101:10
    Lipocalin-2/NGAL1:101:101:101:10
    Osteopontin (OPN)1:101:101:101:10
    RBP41:4,0001:4,0001:4,0001:10
    TFF31:101:101:101:10
    TIM-1/KIM-1/HAVCR1:101:101:101:10

     

    More Information about Magnetic Bead-Based Multiple Kits for the Luminex Platform

    Magnetic  multiplex kits are designed for use with the  CCD Imager. Alternatively, kits can be used with the  or Bio-Rad® Bio-Plex®, dual laser, flow-based sorting and detection platforms.

    Analyte-specific antibodies are pre-coated onto color-coded magnetic microparticles. Microparticles, standards and samples are pipetted into wells and the immobilized antibodies bind the analytes of interest. After washing away any unbound substances, a biotinylated antibody cocktail specific to the analytes of interest is added to each well. Following a wash to remove any unbound biotinylated antibody, streptavidin-phycoerythrin conjugate (Streptavidin-PE), which binds to the biotinylated antibody, is added to each well. A final wash removes unbound Streptavidin-PE, the microparticles are resuspended in buffer and read using the Luminex MAGPIX Analyzer. A magnet in the analyzer captures and holds the superparamagnetic microparticles in a monolayer. Two spectrally distinct Light Emitting Diodes (LEDs) illuminate the beads. One LED identifies the analyte that is being detected and the second LED determines the magnitude of the PE-derived signal, which is in direct proportion to the amount of analyte bound. Each well is imaged with a CCD camera. Kits can also be used with Luminex 100, Luminex 200 or a Bio-Rad Bio-Plex dual laser, flow-based systems.

    Trademarks and registered trademarks are the property of their respective company.

    举报收藏 0评论 0
 
热门项目排行榜快速发布信息
14-(2-碘代乙基)辛基苯 9
2高温波导测试
3格列美脲 98%+ RG  5g
4N,N-Diethyl-cyclohexan
54-溴-3,5-二氯三氟甲苯
6Recombinant Human LILR
标准物质排行榜快速发布信息
1妥布特罗甲醇溶液标准物
2甲醇中沙米特罗溶液标准
3MABTRAP KIT
4ZBTB43基因敲除HEK293T
5Mouse FGF-15 Affinity
6silicone kf-96 chromos
最新加入项目快速发布信息
1TWS用胶
2电感胶
3电子胶
4环氧AB胶
5导电银胶(晶振)
6固晶胶

猜你喜欢产品快速发布信息

相关栏目

还没找到您需要的标准物质产品?立即发布您的求购意向,让标准物质公司主动与您联系!

立即发布项目意向

免责声明

本网页所展示的有关【Human Cystatin C Magnetic Luminex Performance Assay 1 KT_标准物质_云试剂自营四店】的信息/图片/参数等由云试剂的会员【云试剂自营四店】提供,由云试剂会员【云试剂自营四店】自行对信息/图片/参数等的真实性、准确性和合法性负责,本平台(本网站)仅提供展示服务,请谨慎交易,因交易而产生的法律关系及法律纠纷由您自行协商解决,本平台(本网站)对此不承担任何责任。您在本网页可以浏览【Human Cystatin C Magnetic Luminex Performance Assay 1 KT_标准物质_云试剂自营四店】有关的信息/图片/价格等及提供【Human Cystatin C Magnetic Luminex Performance Assay 1 KT_标准物质_云试剂自营四店】的商家公司简介、联系方式等信息。

联系方式

在您的合法权益受到侵害时,欢迎您向邮箱发送邮件,或者进入《网站意见反馈》了解投诉处理流程,我们将竭诚为您服务,感谢您对云试剂的关注与支持!

按排行字母分类找加盟项目:

A B C D E F G H I J K L M N O P Q R S T U V W X Y Z