测量原理
紫外光(UV)光度计
特点
Processanalyzerfortotalnitrogeninaqueoussolutions
UVphotometricmethodfollowingHJ636-2012
尺寸
Housing(openversion):
793x530x417mm
31.22x20.87x16.42in
Housing(closedversion):
793x530x463mm
31.22x20.87x18.23in
Housingwithbase:
1723x530x463mm
67.83x20.87x18.23in
设计
Opendesign,cabinetandstandhousing
High-PerformanceplasticASA-PC,additionalstandcoatedsteel
过程温度
4to40°C(39.2to104°F)
环境温度
5to40°C(41to104°F)
过程压力
Atatmosphericpressure,<0.2bar
探头处的流速
Min.15ml/min(0.51fl.oz/min)
探头的一致性
Aqueous,homogeneous
应用
Monitoringofwastewatertreatmentplantoutlet
Monitoringofthesurfacewaterquality
Monitoringofindustrialwatertreatment
Monitoringandoptimizationofindustrialwastewatertreatmentplants
电源
100to120VAC/200to240VAC±10%
50±1or60±1,2Hz
输出
2x0/4to20mA
ModbusRS485/TCP(optional)
Webserver(optional)
Ethernet/IP
ProfibusDP
Alarmrelay
输入
1measuringchannel
1to4digitalsensorinputsforsensorswithMemosensprotocol(optional)
测量范围
0to10mg/lN
0to50mg/lN
0to200mg/lN
耗材
ReagentsandstandardsolutionsCY80TNaswellascleanerCY800arenecessaryfortheoperation
RegularmaintenanceisdonewiththepartsofthemaintenancekitCAV880
总氮是决定地表水水质和衡量废水排放影响的一个关键指标。总氮包括了水中的有机氮与无机氮。如果地表水中的总氮氮浓度上升则意味着地表水可能受到了管网污水、垃圾渗滤液或者农业面源污染的影响。
LiquilineSystemCA80TN总氮分析仪在线进行高精度总氮测量,为过程安全保驾护航。分析仪配备高级诊断功能,支持远程访问,归档记录可作为证明文件直接提交给权威机构。
LiquilineSystem总氮分析仪监测有机氮化物(例如蛋白质、尿素)和无机氮化物(例如硝酸盐、亚硝酸盐、氨氮),适用于下列应用场合:
污水处理厂的进水口和出水口,进行归档记录和净化能力计算
工业废水处理厂排放量,确定排放费用,是“排污付费原则”的基础
监测地表水水质
符合国家HJ636标准《水质总氮的测定碱性过硫酸钾消解紫外分光光度法》,测量结果与实验室结果完全一致。
坚固耐用:钛材反应器搭配蓝宝石窗口,具有长使用寿命。
使用灵活:内置稀释单元,提供宽量程范围。
快速实现过程集成:自抽取式分析仪直接安全使用,带Y型预处理的分析仪串联在旁路管道中使用。
简单添加模块,连接Memosens数字式传感器,轻松升级至完整的测量站。
监测乳液的聚合反应
通过反应结束检测和动力学控制实现工艺优化
半间歇聚合工艺
拉曼分析仪采用Kaiser拉曼技术,用于监测和控制半间歇聚合工艺